How to Install an Air Fuel Gauge

How to Install an Air Fuel Gauge

0
SHARE

The Air/Fuel Ratio Gauge is a device that measures the presence of oxygen in the exhaust, and is wired into the oxygen sensors of your vehicle. More oxygen in the exhaust is a result of a lean air fuel mixture and less oxygen is the result of a rich mixture. The “perfect” ratio (not rich or lean) of air and fuel is called the Stoichiometric (STOICH) ratio. Once the STOICH Air/Fuel ratio is achieved, the oxygen sensor will be very sensitive (accurate).

This writeup is an overview of what a narrowband 02 sensor is, what it does and how to install it.

GENERAL APPLICATION
12-volt DC negative (-) ground electrical systems (11-16 VDC operating voltage range). Input: 0 to 1 volt from most factory and aftermarket oxygen sensors.

GAUGE MOUNTING (Figure 1)

air-fuel-gauge

 

NOTE: Instructions apply to 2″ & 2-5/8″ gauges (nominal SAE diameters). Be careful when making panel cut-out!

Recommended panel cut-out (hole size) for 2″ nominal gauge is 2.098″ +/- .02″. Recommended panel cut-out (hole size) for 2-5/8″ nominal gauge is 2.670″ +/- .03″.

Secure the gauge in the hole using the supplied retaining bracket, lock washers and #8-32 nuts. Maximum torque for mounting screws is 6 in. lbs. TIP: It may be easier to pre-wire gauge before installing!

AIR/FUEL RATIO GAUGE WIRING

wiring

 

Disconnect negative (-) battery cable. Using 18-ga. wire, connect the (-) terminal to a clean (rust/paint-free) engine ground. Using 18-ga. wire, connect the (+) terminal to a switched +12V source. Using 18-ga. wire, connect the (S) sender terminal to the signal wire from the oxygen sensor (refer to your vehicle service manual or your dealer for hookup location information). NOTE: If you are hooking the signal wire at the oxygen sensor, connect to the vehicle wire harness, not the wires from the sensor.

Connect one (1) of the light wires (WHITE) to the dash lighting circuit or to a +12V switched circuit. Connect other light wire (BLACK) to chassis ground. Reconnect the negative (-) battery cable & test instrument to ensure that it is working.

OXYGEN SENSOR INFORMATION (Figure 3 & 4)
There are two (2) types of oxygen sensors, heated and unheated. The oxygen sensor needs to be at least 600°F in order to produce a signal. The unheated sensor relies on exhaust gases for heat. It can take several minutes to reach 600°F, and may drop below operating temperature while idling.

The heated sensor has an internal heating element, which quickly reaches and maintains operating temperature. The unheated sensor has 1 or possibly 2 wires (figure 3)

wiringgauge

 

The 1-wire sensor has only the signal wire, which goes to the (S) terminal on the gauge. The 2-wire sensor has an additional wire for the signal-ground. The signal-ground wire connects along with the gauge (-) wire to the engine ground. The heated sensor generally has 3 or 4 wires (figure 4)

46

 

On a 3-wire sensor there are generally 2 wires (the same color) for the heater. Connect one wire to ground and the other to a switched 12V source. The third wire is the signal wire, which goes to the (S) terminal on the gauge. The 4-wire sensor is essentially the same as the three 3 wire version except for the additional signal-ground wire which gets connected along with the gauge (-) wire to the engine ground.

USING THE AIR/FUEL RATIO GAUGE
The Air/Fuel Ratio Gauge is essentially a voltmeter that displays the voltage output of an oxygen sensor in order to determine the richness or leanness of the exhaust mixture. It provides four red LEDs (for lean status), ten yellow LEDs (stoichiometric), and six green LEDs (rich). The first LED comes on at .05V, the second at .10V and so on, in increments of .05V.

Although it can not measure exact richness or leanness, the Air/Fuel Ratio Gauge is an excellent indicator of dangerous conditions. For example, a vacuum leak or a drop in fuel pressure could cause a detrimental lean condition. The Air/Fuel Ratio Gauge will show this condition before damage occurs.

When used in a fuel injected application, the PCM (Powertrain Control Module) uses the oxygen sensor to keep the engine running close to the STOICH ratio. It does this by continually leaning the mixture until the sensor shows lean, then richening the mixture until it shows rich.

This continuous loop keeps the air/fuel mixture near the STOICH ratio. Under heavy acceleration the PCM will richen the mixture for optimum power and under deceleration the PCM will lean the mixture for low emissions and economy. The Air/Fuel Ratio Gauge is an excellent choice for monitoring PCM operation.

Although the Air/Fuel Ratio Gauge is a monitoring device, it can be used with a carburetor as a tuning aid. Start with rich jetting, then gradually lean the mixture out until the Air/Fuel Ratio Gauge shows lean, then richen the carburetor back up slightly until there is a rich reading. This should produce the best power, but as always, the final jetting should be verified by inspecting the spark plugs.

CLEANING DIRECTIONS
For proper cleaning of instrumentation/accessories, use a glass cleaner or mild detergent with a spray on and wipe method.

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.